| Brand Name: | SY Hydraulic |
| Model Number: | SY-PGP2 |
| MOQ: | 1PC |
| Payment Terms: | T/T |
| Supply Ability: | 500 pcs per month |
Rexroth PGP2-2X/006RE20VE4 R900932129 Internal Gear Pump | Fixed Displacement Hydraulic Pump
Key Features
1. Axial & radial gap compensation → high volumetric efficiency, low leakage
2. Low pulsation & low noise, suitable for noise-sensitive industrial stations
3. Aluminum housing, compact structure, long service life
4. FKM seal, compatible with mineral oil & eco-friendly hydraulic oil
5. Standard ISO flange & shaft, easy replacement & installation
| Item | Parameter |
| Model | PGP2-2X/006RE20VE4 |
| Material No. | R900932129 |
| Type | Internal Gear Pump, Fixed Displacement |
| Geometric Displacement | 6.3 cm³/rev |
| Continuous Pressure | 250 bar |
| Peak Pressure | 280 bar |
| Rotation Direction | Clockwise (R) |
| Shaft | Φ20mm cylindrical shaft with key, ISO 3019-2 |
| Mounting Flange | 4-hole square flange 80B4SW, ISO 3019-2 |
| Through-drive | Yes |
| Seal Material | FKM |
| Weight | 3.64 kg |
| Speed Range | 500 ~ 3500 rpm |
| Hydraulic Fluid | HLP mineral oil, HEES synthetic ester fluid |
| Working Temperature | -20℃ ~ +80℃ |
| Feature | Gap compensation, low noise, low pulsation |
| Circuit | Open circuit only |
Application
1. Hydraulic power unit, machine tool hydraulic system
2. packaging machinery, textile machinery
3. rubber & plastic machinery, test bench
4. general industrial hydraulic equipment
5. automation production line open circuit hydraulic station.
![]()
Specification:
| Warranty | 1 Year |
| Model | PGP2 |
| Place of Origin | China |
| Type | Hydraulic Gear pump Rexroth |
| Color | Available |
| Feature | High Efficiency,Long Life |
| Delivery Time | 15-30 Days after Payment |
| Condition | Brand new |
Competitive Advantages
The Analysis for Rexroth PGP2 Gear Hydraulic Pump Commom Breakdown:
1. Pressure fluctuation and unstable running: Caused by air in LS signal line, blocked DFR pilot orifice or contaminated oil. Bleed air from LS line, clean control spool and keep hydraulic oil clean.
2. Failed to reduce flow and high system temperature: Caused by stuck DFR control spool or blocked X port unloading passage. Disassemble and clean the DFR regulator and inspect the X port channel.
3. Insufficient pressure and pressure drop under load: Caused by worn valve plate & piston slipper assembly or fatigued compensator spring. Test case drain flow and replace worn parts or pressure spring.